How Variable Refrigerant Flow Works

Using a natural gas-powered engine to drive dual scroll compressors, YANMAR’s Variable Refrigerant Flow (VRF) Heat Pump can maintain powerful heating performance, even with low outdoor temperatures, by capturing heat off the unit’s engine to increase efficiency. Our heat recovery technology loves the cold, effortlessly providing heat in the freezing cold. The unit is not afraid of extreme heat either, easily cooling a building during warmer months. Not only do our VRF units withstand some of the toughest temperatures Mother Nature can deliver, they do it with supreme efficiency. The cost of operating the compressor in our outdoor units is 1/10 the cost of that of a standard electric system, resulting in hundreds to thousands of dollars of savings in electricity costs.

Cooling Cycle

Cooling Cycle

Heating Cycle

Heating Cycle

Benefits

Energy Efficient

By utilizing a highly efficient natural gas-powered variable speed engine to drive dual scroll compressors, the YANMAR VRF system can reduce electricity usage by up to 90% compared to traditional air conditioning systems.

Energy Efficient

Environmental Benefits

Natural gas as an energy source produces significantly lower amounts of harmful emissions: 80% less NOx, 100% less SOx and 35% less CO2 than coal. By utilizing natural gas, YANMAR’s VRF technology not only helps preserve precious energy resources, but also reduces harmful emissions.

Environmental Benefits

Economic Savings

With lower operating and infrastructure costs and greater efficiency, the YANMAR VRF system offers substantially lower system lifecycle costs compared to electric systems on the market today. In fact, our Variable Refrigerant Flow system reduces overall running costs by 30-70% depending on local utility costs.

Economic Savings

Low Operation Noise

YANMAR’s Outdoor Units are reliably quiet. At 3 ft, maximum noise levels are:

  • 57dB(A) NNCP096JN (8rt)
  • 57dB(A) NNCP120JN (10rt)
  • 57dB(A) NNCP144JN (12rt)
  • 58dB(A) NNCP168JN (14rt)
  • 58dB(A) NFCP168JN (14rt-Heat Recovery)

 

Low Operation Noise

High Reliability

Based on YANMAR’s proven engine technology and experience in VRF design, manufacturing, installation and service support, we are able to provide customers with a standard limited warranty.

High Reliability

Easy Installation

YANMAR’s comprehensive technical training curriculum develops certified technicians prepared in all phases of design, installation, commissioning and service.

Easy Installation

Models

Model Cooling Capacity Heating Capacity Low Temp/Cold Temp Heating Number of Pipes
NNCP096J

NNCP096J

8 RT

106,000 BTU

106,000 BTU

2 (Heat or Cool)

NNCP120J

NNCP120J

10 RT

134,000 BTU

137,000 BTU

2 (Heat or Cool)

NNCP144JN

NNCP144JN

12 RT

156,000 BTU

164,000 BTU

2 (Heat or Cool)

NNCP168JN

NNCP168JN

14 RT

189,000 BTU

178,000 BTU

2 (Heat or Cool)

NFZP168JN

NFZP168JN

14 RT

189,000 BTU

178,000 BTU

3 (Heat Recovery)

ENCP710JJ

ENCP710JJ *

20 RT

273,000 BTU

242,300 BTU

2 (Heat or Cool)

ENCP850JJ

ENCP850JJ *

24 RT

324,200 BTU

290,100 BTU

2 (Heat or Cool)

*Non-EPA Compliant, Not for Sale in U.S.

INDOOR UNIT MODEL INFORMATION

Applications

Education

Education

Healthcare

Healthcare

Hotel

Hotel

Multi-unit Housing

Multi-unit Housing

Office

Office

Restaurant

Restaurant

Case Study

Stewart Avenue Public School

Stewart Avenue Public School

16 RT VRF Installation in Cambridge, Ontario

Would you like to reduce your energy costs?

Start your performance summary

FAQs

What makes the YANMAR Variable Registrant Flow (VRF) system unique?

At the heart of every YANMAR VRF system is a reliable and durable YANMAR natural gas-powered engine. This fuel-efficient engine enables the outdoor unit to vary its operating speed according to the cooling or heating demands of the zones it controls. Combined with dual scroll compressors, YANMAR’s system provides precision temperature control to deliver comfort that is naturally reliable and eco-efficient.

What are the advantages of advanced zoning?

With YANMAR multi-zone VRF systems, you have complete control over your environment, as each room or zone can have its own separate Daikin indoor unit (fan and heating/cooling coil) and thermostat. Unoccupied rooms or floors can be shut down individually to reduce energy costs. Plus, during construction or renovation of commercial or multi-family residential buildings, the system’s advanced zoning capabilities allow each floor to be occupied upon completion, while work progresses on other floors.

Can room temperatures be controlled remotely?

Yes. YANMAR systems with Daikin’s super-intelligent, user-friendly system controllers can create comfort quickly and easily. The advanced functionality and easy-to-read liquid crystal displays (LCDs) allow you to orchestrate and monitor mode, temperature, time, airflow volume and more across your entire system at the touch of button.

Does the system produce any power?

No. Variable Refrigerant Flow systems produce heating and cooling for facilities. However, YANMAR also offers micro Combined Heat and Power units that produce both useful heat and power, and work well in conjunction with the VRF system.

Can the unit run during extreme cold periods?

Yes. The VRF runs and heats well during cold periods by using waste heat to increase the amount of heating for the facility. A cold weather kit also adds extra protection by keeping the engine compartment warm even when the engine is not running.

Is there any special equipment required for installing or servicing the system?

No. The same tools that are used for troubleshooting electric systems are also required for installing and maintaining YANMAR’s system.

How much extra maintenance is required?

The outdoor unit requires maintenance every 10,000 hours, which can equate to every two to three years. This maintenance includes changing the oil, filters and plugs.